Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cont Lens Anterior Eye ; : 102133, 2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38467534

RESUMO

BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.

2.
Cont Lens Anterior Eye ; 47(1): 102098, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040556

RESUMO

PURPOSE: To analyze the visual quality of a new multifocal scleral lens with a customized decentred optic zone compared to a conventional design by measuring visual acuity, contrast sensitivity function, stereopsis, subjective vision and comfort after one month of wear. METHODS: Nineteen presbyopic subjects were fitted with two multifocal scleral lens designs: a conventional multifocal and a customized decentred optical zone design. All subjects wore both scleral lens designs for one month with a two-week washout period. The main variables evaluated included high and low-contrast visual acuity under photopic and mesopic light conditions, binocular defocus curves, contrast sensitivity function and a visual analogue scale (VAS) for subjective vision and comfort. RESULTS: Comparing the two scleral lens designs, statistically significant differences in visual acuity were found, highlighting the improvement in more than one chart line (6 letters) for low contrast near tests under photopic light conditions with the decentred optics lens design. VAS questionnaire scores also showed a significant improvement in distance and overall subjective vision with the decentred optics lenses. Contrast sensitivity function showed an improvement with decentred multifocal lenses at all spatial frequencies measured, being statistically significant for 12 cycles per degree. No differences in stereoacuity were found. CONCLUSION: Multifocal scleral lenses with a customized decentred optical zone proved to be a promising refractive correction in presbyopic subjects after one month of wear, offering good comfort and visual quality under photopic and mesopic light conditions.


Assuntos
Lentes Intraoculares , Presbiopia , Humanos , Presbiopia/terapia , Acuidade Visual , Sensibilidades de Contraste , Refração Ocular , Testes Visuais
3.
Eye Contact Lens ; 50(1): 35-40, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38124285

RESUMO

PURPOSE: To compare visual quality, contrast sensitivity, stereopsis, subjective vision, and comfort between monofocal and multifocal scleral lens (SL) designs. METHODS: An experimental, cross over and short-term pilot study has been performed. Nineteen presbyopic patients (51.9±3.8 years) with regular corneas participated voluntarily in the study and Onefit MED monofocal and multifocal SL designs were fitted bilaterally. Subjective vision and comfort, contrast sensitivity function, stereopsis, high- and low-contrast visual acuity (VA) at 4 m and 40 cm under photopic and mesopic conditions, and defocus curves were measured. Data analysis was performed with nonparametric tests. P<0.05 was considered as statistically significant. RESULTS: Mean addition power of the prescribed lenses was 1.72±0.38 diopters. Multifocal design showed a statistically significant improvement for intermediate and near vision in the defocus curve under photopic and mesopic conditions (P<0.05), however, worsening in stereopsis (P<0.05) and contrast sensitivity for high spatial frequencies (P<0.05). Distance visual acuity (VA) showed significantly lower values under mesopic conditions for high- and low-contrast tests (P<0.05), and on low-contrast test under photopic conditions (P<0.001) with the multifocal design. CONCLUSION: Multifocal SLs showed better visual performance at intermediate and near distances without compromising distance vision under photopic conditions for a high-contrast test when compared with monofocal design.


Assuntos
Sensibilidades de Contraste , Lentes Intraoculares , Humanos , Córnea , Percepção de Profundidade , Projetos Piloto , Acuidade Visual
4.
Behav Brain Res ; 339: 286-296, 2018 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-29102592

RESUMO

The water maze is one of the most widely employed spatial learning paradigms in the cognitive profiling of genetically modified mice. Oftentimes, tests of reference memory (RM) and working memory (WM) in the water maze are sequentially evaluated in the same animals. However, critical difference in the rules governing efficient escape from the water between WM and RM tests is expected to promote the adoption of incompatible mnemonic or navigational strategies. Hence, performance in a given test is likely poorer if it follows the other test instead of being conducted first. Yet, the presence of such negative transfer effects (or proactive interference) between WM and RM training in the water maze is often overlooked in the literature. To gauge whether this constitutes a serious concern, the present study determined empirically the magnitude, persistence, and directionality of the transfer effect in wild-type C57BL/6 mice. We contrasted the order of tests between two cohorts of mice. Performance between the two cohorts in the WM and RM tests were then separately compared. We showed that prior training of either test significantly reduced performance in the subsequent one. The statistical effect sizes in both directions were moderate to large. Although extended training could overcome the deficit, it could re-emerge later albeit in a more transient fashion. Whenever RM and WM water maze tests are conducted sequentially in the same animals - regardless of the test order, extra caution is necessary when interpreting the outcomes in the second test. Counterbalancing test orders between animals is recommended.


Assuntos
Atenção/fisiologia , Aprendizagem em Labirinto/fisiologia , Memória de Curto Prazo/fisiologia , Comportamento Espacial/fisiologia , Animais , Comportamento Animal , Masculino , Camundongos Endogâmicos C57BL , Transferência de Experiência/fisiologia
5.
Exp Cell Res ; 350(1): 50-61, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27836810

RESUMO

Polycystin-2 (PC2, TRPP2) is a nonselective cation channel whose dysfunction is associated with the onset of autosomal dominant polycystic kidney disease (ADPKD). PC2 contributes to Ca2+ transport and cell signaling in renal epithelia and other tissues. Little is known however, as to the external Ca2+ regulation of PC2 channel function. In this study, we explored the effect of external Ca2+ on endogenous PC2 in wild type LLC-PK1 renal epithelial cells. We obtained whole cell currents at different external Ca2+ concentrations, and observed that the basal whole cell conductance in normal Ca2+(1.2mM), decreased by 30.2% in zero (nominal) Ca2+ and conversely, increased by 38% in high external Ca2+(6.2mM). The high Ca2+-increased whole cell currents were completely inhibited by either PC2 gene silencing, or intracellular dialysis with active, but not denatured by boiling, PC2 antibody. Exposure of cells to high Ca2+ was also associated with relocation of PC2 to the plasma membrane. To explore whether a Ca2+ sensing receptor (CaSR) was implicated in the external Ca2+ modulation of PC2 currents, we tested the effect of the CaSR agonists, spermine and the calcimimetic R-568, which largely mimicked the effect of high Ca2+ under Ca2+-free conditions. The CaSR agonist gentamicin also increased the PC2 currents in the presence of normal Ca2+. The presence of CaSR was confirmed by immunocytochemistry, which partially colocalized with the intracellular PC2 protein, in an external Ca2+-dependent manner. The data support a novel Ca2+ sensing mechanism for PC2 expression and functional regulation in renal epithelial cells.


Assuntos
Cálcio/metabolismo , Células Epiteliais/metabolismo , Rim/metabolismo , Canais de Cátion TRPP/metabolismo , Animais , Membrana Celular/metabolismo , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...